AVALON FM20 AND FM 30 FETAL MONITORS PDF

The unique Smart Pulse measurement integrated in the Toco transducer simplifies monitoring. Without an additional sensor, the maternal pulse rate is monitored and continuously compared with the heart rate from the fetal sensor cross-channel verification. In combination with an Avalon CL Transducer System all fetal and maternal measurements can be monitored cableless, including twins, triplets, and Smart Pulse. The battery option gives monitoring flexibility e. If an obstetrical information and surveillance system is connected via LAN, another information system EMR can be connected via RS in read-only mode.

Author:JoJohn Brak
Country:Cambodia
Language:English (Spanish)
Genre:Career
Published (Last):8 February 2012
Pages:349
PDF File Size:12.96 Mb
ePub File Size:3.65 Mb
ISBN:594-6-45483-208-6
Downloads:41212
Price:Free* [*Free Regsitration Required]
Uploader:Kazrarisar



The unique Smart Pulse measurement integrated in the Toco transducer simplifies monitoring. Without an additional sensor, the maternal pulse rate is monitored and continuously compared with the heart rate from the fetal sensor cross-channel verification. In combination with an Avalon CL Transducer System all fetal and maternal measurements can be monitored cableless, including twins, triplets, and Smart Pulse.

The battery option gives monitoring flexibility e. If an obstetrical information and surveillance system is connected via LAN, another information system EMR can be connected via RS in read-only mode. The temperature is taken in the ear, but result of this measurement can be automatically adjusted to correspond to a different body reference site. The result is shown on the display of the thermometer and transmitted to the monitor.

For the auscultatory reference the 5th Korotkoff sound was used to determine the diastolic pressure. Deviation: 8 mmHg 1. Measurement Validation: The SpO2 accuracy has been validated in human studies against arterial blood sample reference measured with a CO-oximeter. Pulse oximeter measurements are statistically distributed, only about two-thirds of the measurements can be expected to fall within the specified accuracy compared to COoximeter measurements.

Display Update Period: Typical: 2 seconds, Maximum: 30 seconds. Maximum with noninvasive blood pressure INOP suppression on: 60 seconds. The specified accuracy is the rootmean-square RMS difference between the measured values and the reference values.